5. PARAMETERS
Class No. Symbol
43
*DI2
Input signal selection 2 (CN1B-5)
This parameter is unavailable when parameter No.42 is set to assign
the control change (LOP) to CN1B-pin 5.
Allows any input signal to be assigned to CN1B-pin 5.
Note that the setting digit and assigned signal differ according to the
control mode.
0
Signals that may be assigned in each control mode are indicated
below by their symbols.
Setting of any other signal will be invalid.
Note. P: Position control mode
44
*DI3
Input signal selection 3 (CN1B-14)
Allows any input signal to be assigned to CN1B-pin 14.
The assignable signals and setting method are the same as in input
signal selection 2 (parameter No. 43).
0
This parameter is unavailable when parameter No. 42 is set to
assign the control change (LOP) to CN1B-pin 14.
Name and function
Position
control mode Input signals of
Speed control
mode
Torque control mode
Set value
P
0
SON
1
RES
2
3
PC
4
TL
CR
5
6
7
8
9
A
CM1
B
C
CM2
D
TL1
CDP
E
S: Speed control mode
T: Torque control mode
Position
control mode Input signals of
Speed control
mode
Torque control mode
CN1B-pin 5
selected.
(Note) Control mode
S
T
SON
SON
RES
RES
PC
TL
CR
CR
SP1
SP1
SP2
SP2
ST1
RS2
ST2
RS1
SP3
SP3
TL1
TL1
CDP
CDP
CN1B-pin 14
selected.
5 - 18
Initial
Setting
Control
Unit
value
range
mode
0111
P S T
Refer to
Name
and
function
column.
0222
P S T
Refer to
Name
and
function
column.