5. PARAMETERS
Class No. Symbol
21
*OP3
Function selection 3 (Command pulse selection)
Used to select the input form of the pulse train input signal.
(Refer to Section 3.4.1.)
22
*OP4
Function selection 4
Used to select stop processing at forward rotation stroke end (LSP)
reverse rotation stroke end (LSN) off and choose VC/VLA voltage
averaging.
Name and function
0 0
Command pulse train input form
0: Forward/reverse rotation pulse train
1: Signed pulse train
2: A/B phase pulse train
Pulse train logic selection
0: Positive logic
1: Negative logic
0
0
How to make a stop when forward
rotation stroke end (LSP)
reverse rotation stroke end (LSN)
is valid. (Refer to Section 5.2.3.)
0: Sudden stop
1: Slow stop
VC/VLA voltage averaging
Used to set the filtering time when the
analog speed command (VC) voltage
or analog speed limit (VLA) is imported.
Set 0 to vary the speed to voltage fluctua-
tion in real time. Increase the set value
to vary the speed slower to voltage flu-
ctuation.
Set value
0
1
2
3
4
Filtering time [ms]
0
0.444
0.888
1.777
3.555
5 - 14
Initial
Setting
Control
Unit
value
range
mode
0000
Refer to
Name
and
function
column.
0000
Refer to
Name
and
function
column.
P S T