Inspection Of Rectifier (P8-8) - TOHATSU MFS 4 Service Manual

Table of Contents

Advertisement

3. Difference item

2) Inspection of Rectifier (P8-8)

1.
Check conduction of fuse (10 A) contained in the fuse box
1. Replace if non-conductive.
2.
Check conduction between rectifier terminals. Replace if
out of specification.
Rectifier tester check chart (3GR-76060-0)
Yellow
a
Yellow
a
Black
b
Red
c
Circuit tester: HIOKI3030 (Measurement range:1k½)
he measurement varies depending on the measurement range of the circuit tester or voltage
due to diode used in the unit.
his check provide only a reference, and it is impossible to perform perfect check.
11-38
Yellow
Yellow
a
(
°
(
)
ON
(
°
)
(8 k½)
ON
ON
(7 k½)
(7 k½)
c
ester Ò+Ó terminal
Black
b
a
ON
°
)
(7 k½)
ON
(7 k½)
ON
(7 k½)
b
a
1
Red
c
°
(
)
°
(
)
(
°
)
4st 4/5/6 2011