HORIZONTAL VENT HEAT SHIELD
1.
Loosen, but do not remove center
three screws on top of fireplace.
ATTACHMENT SCREWS
IMPORTANT:
HEAT SHIELD INCLUDED WITH THIS
FIREPLACE MUST BE INSTALLED
WHEN USING A 90-DEGREE ELBOW
DIRECTLY OFF THE TOP OF UNIT TO
HORIZONTALLY POSITION THE
VENT SYSTEM. THIS INCLUDES ANY
CORNER INSTALLATION
VENTING
2. Bend horizontal heat shield at perforation to a 90° angle. Slide the
3. Re-tighten screws.
THE HORIZONTAL
.
PAGE 26
(3) slots on horizontal vent heat shield under loosened screws.
NOTE:
STAND-OFF HEAT SHIELD
NOT SHOWN FOR CLARITY
PURPOSES ONLY.
90° ANGLE BEND