5.13.4 Select welding current
The user has two options for setting the required welding current:
•
Using the sheet metal thickness
•
Directly as welding current
The welding current is displayed in the left-hand display. The "Material thickness" parameter can
be selected in the right-hand display.
Control element Action
5.13.5 Welding data display
The following welding parameters can be displayed before (nominal values), during (actual values) or
after welding (hold values):
Parameter
Welding current
Parameter times
Frequency, balance
Parameter currents
Material thickness
Welding voltage
JOB number
Program number
After welding the hold values are displayed. When changes are made to the settings (e.g. welding
current) after welding, the display switches to the relevant nominal values.
The right-hand display automatically switches over to the material thickness after approx. 4 seconds.
If the "Program number" signal light is on in addition to the "Material thickness" signal light, the user is in
program mode- See 5.15 Welding programs chapter.
If the "JOB number" signal light is on in addition to the "Material thickness" light, the user is in a JOB in
the free memory.
099-000115-EW501
17.06.2015
Result
Press button until signal light
X x
Material Thickness comes on.
Set welding current or sheet metal thickness.
"Left-hand display"
Before welding
(nominal values)
"Right-hand display"
During welding
(actual values)
-
-
-
-
-
-
Design and function
TIG Synergic operating principle
Display (right)
Material thickness in
mm is displayed.
Welding current and
sheet metal thickness
are displayed
After welding
(hold values)
-
-
-
-
-
-
63