5.19.2 Remote control connection socket, 19-pole

Pos.
Pin
1
A
2
B/L
3
F
4
C
5
D
6
J/U
7
K
8
V
9
R
10
H
11
M/N/P
12
G
099-000115-EW501
17.06.2015
Signal shape Designation
Output
Connection for cable screen (PE)
Output
Current flows signal I>0, galvanically isolated (max. +- 15V/100mA)
Output
Reference voltage for potentiometer 10V (max. 10mA)
Input
Control value specification for main current, 0-10V (0V = I
I
)
max
Input
Control value specification for secondary current, 0-10V (0V = I
= I
)
max
Output
Reference 0V
Output
Power supply +15V, max. 75mA
Output
Power supply -15V, max. 25mA
Input
Start/Stop welding current
Input
Switching between main and secondary welding currents (pulses)
Input
Activation of control voltage specification
Set all 3 signals to reference potential 0V to activate external control
voltage specification for main and secondary currents
Output
Measured value I
Design and function
Figure 5-54
(1V = 100A)
SETPOINT
Interfaces for automation
, 10V =
min
, 10V
min
109