Machine description – quick overview
Machine control – Operating elements
Item Symbol
13
14
4.8.1

Function sequence

Item Symbol
1
sec
2
3
AMP%
4
sec
5
AMP
6
sec
30
Description
0
Status displays
After each completed welding task, the last values used in the welding
process for the welding current and welding voltage are shown on the
displays, and the signal light will be on
Direct current welding
Alternating current welding
and
simultaneously: Alternating current welding, AC special
Function sequence (see next chapter)
Description
0
Select welding parameters button
This button is used to select the welding parameters depending on the welding process
and operating mode used.
Gas pre-flow time (TIG)
absolute setting range 0.0 sec to 20.0 sec (0.1s increments).
Ignition current (TIG)
Percentage of the main current.
Setting range 1 % to 200 %
(1 % increments). There are no pulses
during the ignition current phase.
Up-slope time (TIG)
Setting ranges: 0.00 s to 20.0 s
(0.1 s increments).
The up-slope time can be set separately
for non-latched and latched.
Main current (TIG) / pulse current
I min to I max (1 A increments)
Pulse time / slope time from AMP% to AMP
Pulse time setting range: 0.01 s to 20.0 s
(0.01 s increments < 0.5 s; 0.1 s increments > 0.5 s)
Slope time (tS2) setting range: 0.0 s to 20.0 s
- See 5.13.12 Pulse variants chapter
TIG pulses
The pulse time applies to the main current
phase (AMP) for pulses.
Figure 4-7
Hotstart current (MMA)
Percentage of the main current. Setting
range 1 % to 200 %
(1 % increments).
Hotstart time (MMA)
Setting ranges: 0.00 s to 20.0 s
(0.1 s increments).
Main current (MMA)
I min to I max (1 A increments)
TIG AC Special
The pulse time applies to the AC phase for
AC special.
099-000115-EW501