Tetrix 451 Ac/Dc Aw - EWM Tetrix 351 Operating Instructions Manual

Hide thumbs Also See for Tetrix 351:
Table of Contents

Advertisement

Technical data

Tetrix 451 AC/DC AW

8.2
Tetrix 451 AC/DC AW
Welding current
Welding voltage
Duty cycle at 25 °C
100% DC
Duty cycle at 40 °C
80% DC
100% DC
Load cycle
Open circuit voltage (DC)
Mains voltage (tolerances)
Frequency
Mains fuse
(safety fuse, slow-blow)
Mains connection lead
Max. connected load (TIG)
Max. connected load (MMA)
Recommended generator rating
cos/efficiency
Insulation class/protection
classification
Ambient temperature*
Machine/torch cooling
Cooling capacity at 1 l/min
Max. flow rate
Max. coolant outlet pressure
Max. tank capacity
Workpiece lead < 5 m
Workpiece lead > 5 m
Dimensions L/W/H [mm]
Weight
EMC class
Constructed to standard
*Ambient temperature depends on coolant! Observe the coolant temperature range for the
welding torch cooling!
130
TIG
5 A–450 A
10.2 V–28.0 V
450 A
450 A
420 A
10 min. (60% DC
6 min. welding, 4min. pause)
79 V
3 x 400 V (-25% to +20%)
50/60 Hz
3 x 32 A
H07RN-F4G6
16.3 kVA
22.0 kVA
29.7 kVA
0.99/85%
H/IP 23
-25 C to +40 C
Fan/water
1500 W
5 l/min
3.5 bar
12 l
70 mm
95 mm
1080 x 690 x 1195
184.5 kg
A
IEC 60974-1, -2, -3, -10;
;
MMA
20.2 V–38.0 V
2
2
099-000115-EW501
17.06.2015

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tetrix 451Tetrix 551

Table of Contents