Design and function

Interfaces for automation

5.19
Interfaces for automation
Damage to the machine due to improper connection!
Unsuitable control leads or incorrect connection of input and output signals can cause
damage to the machine.
Only use shielded control leads!
If the machine is to be operated with control voltages connection via suitable isolation
amplifiers is required!
To control the main or secondary current via control voltages, the relevant inputs must be
enabled (see specification for activation of control voltage).

5.19.1 TIG interface for mechanised welding

Signal
Pin
shape
A
Output
B
Output
C
Input
Input
D
(no c.)
Input
E
+
R
Output
F
Output
G
-
H
Output
J
K
Input
L
Input
M
Output
Output
N
P
-
S
Output
T
Output
U
V
Output
108
CAUTION
Designation
PE
Connection for cable screen
REGaus
For servicing purposes only
SYN_E
Synchronisation for master/slave operation
IGRO
Current flows signal I>0 (maximum load
20mA / 15V)
0V = welding current flowing
Not/Aus
Emergency stop for higher level shut-down
of the power source.
To use this function, jumper 1 must be
unplugged on PCB T320/1 in the welding
machine. Contact open  welding current
off
0V
Reference potential
NC
Not assigned
Uist
Actual welding voltage, measured on pin F,
0-10V (0V = 0V, 10V = 100V)
Vschweiss Reserved for special purposes
SYN_A
Synchronisation for master/slave operation
Str/Stp
Start / stop welding current, same as torch
trigger.
Only available in non-latched operating
mode. +15V = start, 0V  stop
+15V
Voltage supply
+15V, max. 75mA
-15V
Voltage supply
-15V, max. 25mA
NC
Not assigned
0V
Reference potential
Iist
Actual welding current, measured on pin F;
0-10V (0V = 0A, 10V = 1000A)
NC
SYN_A 0V Synchronisation for master/slave operation
Diagram
099-000115-EW501
17.06.2015

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tetrix 451Tetrix 551

Table of Contents