Welding Programs - EWM Tetrix 351 Operating Instructions Manual

Hide thumbs Also See for Tetrix 351:
Table of Contents

Advertisement

Design and function

Welding programs

5.15
Welding programs
Changes made to the other welding parameters during the course of the program have the
equivalent effect on all programs.
The change to the welding parameters is saved immediately in the JOB.
The welding machine has 16 programs, which you can change during welding.
In each selected welding task (JOB), - See 5.13.3 Select welding task chapter, 16 programs can be set,
saved and called up. In program "0" (default setting) the welding current can be infinitely adjusted across
the entire range. In programs 1-15, 15 different welding currents (incl. operating mode and pulse function)
are defined.
Example:
Program number
1
2
The operating mode cannot be changed during the welding process. If welding is started with program 1
(non-latched operating mode), program 2 controls the setting of ignition program 1 despite the latched
setting and is implemented to the end of the welding process.
The pulse function (pulses off, pulses on) and the welding currents are transferred from the
corresponding programs.
96
Welding current
80A
70A
Operating mode
Non-latched
Latched
Pulse function
Pulses on
Pulses off
099-000115-EW501
17.06.2015

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tetrix 451Tetrix 551

Table of Contents