Maintenance, Care And Disposal; Maintenance Work; General; Maintenance Work, Intervals - EWM Tetrix 351 Operating Instructions Manual

Hide thumbs Also See for Tetrix 351:
Table of Contents

Advertisement

Maintenance, care and disposal

Maintenance work

Maintenance, care and disposal
6
Do not carry out any unauthorised repairs or modifications!
To avoid injury and equipment damage, the unit must only be repaired or modified by
specialist, skilled persons!
The warranty becomes null and void in the event of unauthorised interference.
Appoint only skilled persons for repair work (trained service personnel)!
Risk of injury from electric shock!
Cleaning machines that are not disconnected from the mains can lead to serious
injuries!
Disconnect the machine completely from the mains.
Remove the mains plug!
Wait for 4 minutes until the capacitors have discharged!
6.1
Maintenance work
Repair and maintenance work may only be performed by qualified authorised personnel; otherwise the
right to claim under warranty is void. In all service matters, always consult the dealer who supplied the
machine. Return deliveries of defective equipment subject to warranty may only be made through your
dealer. When replacing parts, use only original spare parts. When ordering spare parts, please quote the
machine type, serial number and item number of the machine, as well as the type designation and item
number of the spare part.
6.2

General

When used in the specified environmental conditions and under normal operating conditions, this
machine is largely maintenance-free and requires a minimum of care.
There are some points, which should be observed, to guarantee fault-free operation of your welding
machine. Among these are regular cleaning and checking as described below, depending on the pollution
level of the environment and the length of time the unit is in use.
6.3

Maintenance work, intervals

6.3.1

Daily maintenance tasks

6.3.1.1

Visual inspection

Mains supply lead and its strain relief
Check the wearing parts in the torch.
Check torch, hose package and power connections for exterior damage and replace or have repaired
by specialist staff as necessary!
Other, general condition
6.3.1.2

Functional test

Operating, message, safety and adjustment devices (Functional test)
Check correct mounting of the wire spool.
Purge the wire guide from the direction of the Euro torch connector with oil- and condensate-free
compressed air or shielding gas.
Welding current cables (check that they are fitted correctly and secured)
Gas tubes and their switching equipment (solenoid valve)
Gas cylinder securing elements
118
DANGER
099-000115-EW501
17.06.2015

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tetrix 451Tetrix 551

Table of Contents