Design and function
TIG Synergic operating principle
5.16.3 Select welding task
The welding task is selected using the buttons on the machine control on the welding machine.
Signal lights (LED) display the welding parameter selection.
It is only possible to change the basic welding parameters if:
•
No welding current is flowing and
•
The key switch (option) is set to position "1".
Operating
element
5.16.4 Select welding current
The user has two options for setting the required welding current:
•
Using the sheet metal thickness
•
Directly as welding current
The welding current is displayed in the left-hand display. The "Material thickness" parameter can
be selected in the right-hand display.
Control element Action
56
Action
Result
Select and display welding process.
Select and display electrode diameter / ignition optimisation.
•
TIG - Synergic:
Select electrode diameter (ignition optimisation is determined
automatically).
•
TIG - Manual:
Select ignition optimisation.
Select and display material type or welding current polarity.
•
TIG - Synergic:
Select material type (welding current polarity is determined
automatically).
•
TIG - Manual:
Select welding current polarity.
Select and display seam type.
Select and display operating mode.
Result
Press button until signal light
X x
Material Thickness comes on.
Set welding current or sheet metal thickness.
NOTE
Display (right)
Material thickness in
mm is displayed.
Welding current and
sheet metal thickness
are displayed