Design and function
Remote control

5.17.7 Manual remote control RT PWS 1 19POL

5.17.8 Foot-operated remote control RTF1 19POL 5 M / RTF2 19POL 5 M

ActivArc welding is not possible in combination with the foot-operated remote control.
Symbol
Meaning
Actuate foot-operated remote control (start welding process)
Operate foot-operated remote control (set welding current according to application)
Release foot-operated remote control (end welding process)
FFr
RTF ramp function
on
off
104
Functions
Infinitely adjustable welding current (0% to 100%) depending on the preselected
main current at the welding machine
Pole reversing switch, suitable for machines with PWS function
Functions
Infinitely adjustable welding current (0% to 100%) depending on the preselected
main current on the welding machine.
Start/stop welding operation (TIG)
Welding current runs in a ramp function at the specified main current
Welding current goes immediately to the specified main current
Figure 5-52
099-000115-EW501