Fireplace Description
The Proflame 2 Remote Control Fireplace consists of three elements:
1. Pro ame 2 Remote Control Transmitter.
2. Pro ame Integrated Fireplace Control (IFC) board (Figure 30) and a wiring harness to connect the IFC to
the gas valve and stepper motor.
3. Wall mounted Remote Control Receiver - page 40.
Transmitter (Remote Control with LCD Display)
The Pro ame 2 Transmitter uses a streamline design with a simple key layout and an informative LCD display
(Figure 62). The remote control transmitter is powered by 3 AAA batteries. A mode key is provided to index
between the features and a thermostat key is used to turn on/off or index through thermostat functions
(Figure 63).
IFC Module
The Pro ame 2 Integrated Fireplace Control (IFC) module is a device that allows automatic ignition and pilot
ame supervision and commands the functions of the replace. It's con gured to control the ON/OFF main
burner operation, giving the choice of both IPI (intermittent pilot ignition), and CPI (continuous pilot ignition)
modes. The Pro ame 2 IFC module controls and connects directly to the pilot assembly and the automatic
valve using low electric power.
The IFC module can be powered by both an AC power supply, and battery pack for back up. The Pro ame 2
offers the added ability to control the comfort fan speed from OFF through six (6) speeds, and remotely actu-
ated dimmable lights. The external batteries can provide DC power to the IFC allowing the batteries to be
used only when line power is interrupted or lost, and if the replace does not use a power vent.

Operating Procedure

Initializing the Fireplace for the first time
1. With the replace main circuit breaker in the OFF position, Install 4 AA batteries into the Town & Country
wall switch battery holder (Figure 65) located behind the wall switch face plate (Figure 66). Make sure that
the selection switch is on the "Remote" setting.
2. Install 3 AAA batteries into the Pro ame 2 Remote Control Transmitter (Figure 62).
3. Turn ON the replace main circuit breaker and open the gas supply line (if valve is present and accessible).
4. Insert a straightened paper clip into the opening marked "Program" of the Town & Country wall switch
(Figure 66) and press the program button once. The IFC module, also located on the inside of the replace
enclosure, will beep 3 times indicating that it is ready to synchronize with a remote control transmitter.
5. On the remote control transmitter, push the "power on" key once. The remote control transmitter will beep
4 times to indicate that the remote control transmitter and the IFC module are now synchronized. The
remote control transmitter is now ready to use.