Wall Termination Venting Chart - Town & Country Fireplaces TC36 Instruction Manual

Table of Contents

Advertisement

24" Pipe
length
minimum
* 68 1/2"
Figure 41:
TC36D Horizontal Run Rise Model.
5056.427D

Wall Termination Venting Chart

**
A
Minimum rise
68 1/2"
72 3/4"
78 3/4"
84 3/4"
92 1/2"
** All dimensions are approximate. Both rise and run may vary with different
combinations of pipe.
B
Pipe length
Maximum run
1-24"
1-12" 1-18"
1-24" 1-12"
1-24" 1-18"
15' 10 1/2"
1-48"
20' 10 1/2"
For other rise/run combinations see chart below
NOTE: The vent must not exceed a total length of 68 feet. Any
combination of rise and run may be used but must be constrained
to the boundaries of this chart. A total of 3 - 90° elbows or
combination of other elbows equalling 90° can be used without
reducing horizontal run. For each additional 90° elbow, or an
equal combination of elbows, reduce horizontal vent run by 2
feet. Ensure vent pipe is properly supported.
24
D
C
Pipe length
Max.
20 1/2"
1-12"
75 3/4"
1-48" 1-12"
11' 2"
2-48" 1-24"
3-48" 1-24"
1-12"
5-48"
TC36_D & TC36_DAR_101215-52