Wall Switch And Remote Control; Selecting Natural Vent And Power Vent Modes - Town & Country Fireplaces TC36 Instruction Manual

Table of Contents

Advertisement

Figure 31: Town & Country
wall switch.
Linking the remote control unit
to the wall switch.
1. Begin by moving the selector
toggle on the wall switch to the
"REMOTE" position.
NOTE: The wall switch comes with the lower ethernet cable blocked with a piece of red tape. If
connecting to a customer supplied home automation system, remove the piece of tape
to connect with the home automation system. If not using a home automation system,
leave the piece of tape in place and use the unblocked port to connect to the IFC module
of the fireplace.

Selecting Natural Vent and Power Vent Modes

The PV / NV (Power Vent / Natural Vent) switch (Figure 34) on the
interface board (Figure 30) is set according to which type of evacuating
vent system is present. If the replace is vented without the assistance
of a power vent, the switch should be set to "NV". If using a power
vent, "PV" should be selected. Follow the instructions provided with
the power vent kit for proper installation.
Important Note:
When switching between PV and NV, both the electrical power supply
to the replace must be turned off and the backup batteries removed to
properly re-set the module.
5056.427D

Wall Switch and Remote Control

TO FIREPLACE
Figure 32: Wall switch interface side.
2. Insert a straightened paper clip
into the "PROGRAM" slot (Figure
31) on the wall switch.
3. Press the internal "PROGRAM"
button once and wait until you
hear 3 beeps from the wall switch.
Figure 33: Wall switch battery side.
4. Press the ON/OFF button of the
5. The toggle on the wall switch
Figure 34: Vent mode selection switch.
18
remote unit. Once the wall unit
beeps 3 times, the remote is
programmed.
must be kept in the "REMOTE"
position in order to use the remote
control unit.
TC36_D & TC36_DAR_101215-52