Operating Instructions supplied with the fi replace and should be kept together. Refer to the Installation and Operating Instructions for proper gas supply, safety requirements and operating instructions TC36 HEARTWOOD BURNER INSTALLATION INSTRUCTIONS PART# TC36.NG05C FOR TC36 & TC36 AR Series C 050411-16 TC36.NG05C 5056.427C45...
Contents of Package • BURNER ASSEMBLY (including pilot and manifold) • LOG GRATE • TC36 HEARTWOOD LOGS • EMBER MATERIAL • HARDWARE PACKAGE • COAL CHUNKS • VERMICULITE Burner Installation Fig. # 1a Place the keyhole slots in the burner...
Page 3
Red end to the connector marked by the red dot, white end to the connector marked 2 SCREWS by the white dot Fig.#2 & Fig.#3 BULKHEAD PLATE Fig. # 3 WHITE END TO RED END TO MODULE WHITE DOT RED DOT TC36.NG05C 050411-16...
Page 4
PILOT SUPPLY TUBE MAIN GAS SUPPLY TUBE 6. Position the slots of the grate securing Fig. # 4 brackets over the holes in the fl oor shield and secure with the two screws (Fig. # 4). TC36.NG05C 050411-16...
Reduce the amount used on Propane models, as too much will create soot Embers only in this area. Embers only in this area. Fig. #6 Embers, coal chunks and lava rock. Embers, coal chunks and lava rock. TC36.NG05C 050411-16...
(fi g. # 7-15) Note: Improper placement of logs will cause sooting on internal parts and glass. The logs may need to be repositioned slightly to avoid excessive fl ame impingement. Fig. # 8 LEFT CENTER LOG, #2 TC36.NG05C 050411-16...
Page 7
Fig. #9 LEFT FRONT LOG, #3 Fig. #10 LOG WITH HOLE, #4 TC36.NG05C 050411-16...
Page 8
Fig. #11 RIGHT CENTER LOG, #5 Fig. #12 FRONT RIGHT LOG, #6 TC36.NG05C 050411-16...
Page 9
Fig. #13 RIGHT BASE LOG, #7 Fig. #14 CENTER TWIG, #8 Fig. #15 CENTER BASE CHUNK, #9 TC36.NG05C 050411-16...
(#45) (our part # 5021.34) (Fig. #18) CAUTION The gas supply and electrical power Fully open the primary air shutter. must be shut off before proceeding with the conversion. Reinstall the manifold assembly and air defl ector. TC36.NG05C 050411-16...
Page 11
(Fig. #20 shows NG position, Fig. # 21 shows LP position) Fig. #21 HOLE Fig. # 22 Remove the minimum rate screw located in the valve. (Fig. #22) Minimum rate screw TC36.NG05C 050411-16...
Page 12
Fig #26 14. Attach the access panel to the side of the fi rebox with the previously removed screws. (Fig. #26) Note: Gasket must be installed with access panel. TC36.NG05C 050411-16...
2. Remove the log set and set aside. 3. Loosen the screw in the Primary Air Shut- ter. 4. Rotate the shutter to increase or decrease the amount of primary air. 5. Reassemble in reverse order. Fig. # 31 PRIMARY AIR SHUTTER TC36.NG05C 050411-16...