Option
Terminal
Code
Symbol
UDC
Remote Control Data
Clearing
OPE
Operator Control
SF1
Multi-speed Select,
Bit operation Bit 1
SF2
Multi-speed Select,
Bit operation Bit 2
SF3
Multi-speed Select,
Bit operation Bit 3
SF4
Multi-speed Select,
Bit operation Bit 4
SF5
Multi-speed Select,
Bit operation Bit 5
SF6
Multi-speed Select,
Bit operation Bit 6
SF7
Multi-speed Select,
Bit operation Bit 7
OLR
Overload Restriction
Source Changeover
TL
Torque Limit Selection
TRQ1
Torque limit switch 1
TRQ2
Torque limit switch 2
BOK
Brake confirmation
LAC
LAD cancellation
PCLR
Pulse counter clear
ADD
ADD frequency enable ON
F-TM
Force Terminal Mode
ATR
Enable torque
command input
KHC
Clear watt-hour data
MI1
General purpose input
(1)
MI2
General purpose input
(2)
Input Function Summary Table
Function Name
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Description
Clears the UP/DWN frequency memory by forcing it to
equal the set frequency parameter F001. Setting
must be set= to enable this function to work
UP/DWN frequency memory is not changed
Forces the source of the output frequency setting
and the source of the Run command to be from
the digital operator
Source of output frequency set by and source of
Run command set by is used
Bit encoded speed select, Bit 1, logical 1
Bit encoded speed select, Bit 1, logical 0
Bit encoded speed select, Bit 2, logical 1
Bit encoded speed select, Bit 2, logical 0
Bit encoded speed select, Bit 3, logical 1
Bit encoded speed select, Bit 3, logical 0
Bit encoded speed select, Bit 4, logical 1
Bit encoded speed select, Bit 4, logical 0
Bit encoded speed select, Bit 5, logical 1
Bit encoded speed select, Bit 5, logical 0
Bit encoded speed select, Bit 6, logical 1
Bit encoded speed select, Bit 6, logical 0
Bit encoded speed select, Bit 7, logical 1
Bit encoded speed select, Bit 7, logical 0
Perform overload restriction
Normal operation
Setting of is enabled
Max. torque is limited with 200%
Torque limit related parameters of Powering/regen, and
FW/RV modes are selected by the combinations of
these inputs.
Brake wait time () is valid
Brake wait time () is not valid
Set ramp times are ignored. Inverter output
immediately follows the freq. command.
Accel. and/or decel. is according to the
set ramp time
Clear the position deviation data
Maintain the position deviation data
Adds the (add frequency) value
to the output frequency
Does not add the value to the
output frequency
Force inverter to use input terminals
for output frequency and Run command sources
Source of output frequency set by and source of
Run command set by is used
Torque control command input is enabled
Torque control command input is disabled
Clear watt-hour data
No action
General purpose input (1) is made ON under EzSQ
General purpose input (1) is made OFF under EzSQ
General purpose input (2) is made ON under EzSQ
General purpose input (2) is made OFF under EzSQ
76