Func.
Name
Code
Overload restriction level 2
Deceleration rate 2 at overload
restriction
OC suppression selection
Current level of active freq.
matching
Deceleration rate of active
freq. matching
Start freq. of active freq.
matching
Software lock mode selection
Motor cable length parameter
Run/power ON warning time
Rotation direction restriction
Reduced voltage start
selection
"b" Function
Description
Sets the level of overload restriction,
between 20% and 200% of the rated
current of the inverter, setting
resolution is 1% of rated current
Sets the deceleration rate when
inverter detects overload, range is
0.1 to 3000.0, resolution 0.1
Two option codes:
Disabled
Enabled
Sets the current level of active freq.
matching restart, range is
0.1*inverter rated current to
2.0*inverter rated current, resolution
0.1
Sets the deceleration rate when
active freq. matching restart, range
is 0.1 to 3000.0, resolution 0.1
Three option codes:
freq at previous shutoff
start from max. Hz
start from set frequency
Prevents parameter changes, in five
options, option codes:
all parameters except are
locked when [SFT] terminal is
ON
all parameters except and
output frequency are
locked when [SFT] terminal is
ON
all parameters except are
locked
all parameters except and
output frequency are
locked
High level access including
See the row "Run Mode Edit" for the
accessible parameters in this mode.
Set range is 5 to 20.
Range is,
.:Warning disabled
. to .:
10 to 99,990 hrs (unit: 10)
to :
100,000 to 655,350 hrs (unit: 100)
Three option codes:
No restriction
Reverse rotation is restricted
Forward rotation is restricted
Set range, (disabling the function),
(approx. 6ms) to (approx.
1.5s)
63
Run
Defaults
Mode
Initial data
Units
Edit
Rated
current
x 1.5
1.0
sec.
00
Rated
A
current
0.5
sec.
00
01
10.
0.
Hrs.
00
2