Func.
Name
Code

[OI] input active range end
current

[OI] input start frequency
select

Acceleration curve constant

Deceleration curve constant

A input select for calculate
function

B input select for calculate
function

Calculation symbol

ADD frequency

ADD direction select

Curvature of EL-S-curve at the
start of acceleration

Curvature of EL-S-curve at the
end of acceleration

Curvature of EL-S-curve at the
start of deceleration
"A" Function
Description
The ending point (offset) for the
current input range,
range is 0. to 100.%
Two options; select codes:
Use offset ( value)
Use 0Hz
Range is 01 to 10.
Range is 01 to 10.
Seven options:
Operator
VR
Terminal [O] input
Terminal [OI] input
RS485
Option
Pulse train input
Seven options:
Operator
VR
Terminal [O] input
Terminal [OI] input
RS485
Option
Pulse train input
Calculates a value based on the
A input source ( selects) and
B input source ( selects).
Three options:
ADD (A input + B input)
SUB (A input - B input)
MUL (A input * B input)
An offset value that is applied to
the output frequency when the
[ADD] terminal is ON.
Range is 0.0 to 400.(1000)
Two options:
Plus (adds  value to the
output frequency setting)
Minus (subtracts  value
from the output frequency
setting)
Range is 0 to 50%
Range is 0 to 50%
Range is 0 to 50%
59
Run
Mode
Initial data
Edit
100.
00
02
02
02
03
00
0.00
*1
Hz
00
10.
10.
10.
Defaults
Units
%
Hz
%
%
%

Hide quick links: