Motor Constants Functions
Func.
Name
Code
Auto-tuning selection
Motor constant selection
Motor constant selection,
nd
2
motor
Motor capacity
Motor capacity,
nd
2
motor
Motor poles setting
Motor poles setting,
nd
2
motor
Motor speed response
constant
Motor speed response
nd
constant, 2
Motor stabilization constant
Motor stabilization
nd
constant, 2
Motor constant R1
(Hitachi motor)
Motor constant R1,
nd
2
motor (Hitachi motor)
Motor constant R2
(Hitachi motor)
Motor constant R2,
nd
2
motor (Hitachi motor)
Motor constant L
(Hitachi motor)
Motor constant L,
nd
2
motor (Hitachi motor)
Motor constant I0
(Hitachi motor)
Motor constant I0,
nd
2
motor (Hitachi motor)
Motor constant J
(Hitachi motor)
Motor constant J,
nd
2
motor (Hitachi motor)
Motor constant R1
(Auto tuned data)
Motor constant R1,
nd
2
motor (Auto tuned data)
"H" Function
Three option codes:
Disabled
Enabled with motor stop
Enabled with motor rotation
Two option codes:
Hitachi standard motor
Auto tuned data
Twelve selections:
0.1/0.2/0.4/0.75/1.5/2.2/3.7/
5.5/7.5/11/15/18.5
Five selections:
2 / 4 / 6 / 8 / 10
Set range is 1 to 1000
motor
Motor constant (factory set),
range is 0 to 255
motor
0.001 to 65.535 ohms
0.001 to 65.535 ohms
0.01 to 655.35mH
0.01 to 655.35A
0.001 to 9999 kgm
0.001 to 65.535 ohms
Description
2
81
Defaults
Run
Mode
Initial data
Edit
00
00
00
Specified by
the capacity of
each inverter
model
4
4
100.
100.
100.
100.
Specified by
the capacity of
each inverter
mode
Specified by
the capacity of
each inverter
Units
-
-
-
kW
kW
poles
poles
-
-
Ohm
Ohm
Ohm
Ohm
mH
mH
A
A
2
kgm
2
kgm
ohm
ohm