Hitachi WJ200-001S Quick Reference Manual page 29

Wj200 series
Hide thumbs Also See for WJ200-001S:
Table of Contents

Advertisement

Recommended ferrule
For safe wiring and reliability, it is recommended to use following ferrules.
Wire size
Model name of
2
mm
(AWG)
0.25 (24)
0.34 (22)
0.5 (20)
0.75 (18)
* Supplier: Phoenix contact
Crimping pliers: CRIPMFOX UD 6-4 or CRIMPFOX ZA 3
How to connect?
(1) Push down an orange actuating lever by a slotted screwdriver (width 2.5mm max.).
(2) Plug in the conductor.
(3) Pull out the screwdriver then the conductor is fixed.
2.5mm
ferrule *
AI 0.25-8YE
AI 0.34-8TQ
AI 0.5-8WH
AI 0.75-8GY
Φd [mm]
L [mm]
12.5
0.8
12.5
0.8
14
1.1
14
1.3
Push down an
orange actuating
lever.
27
ΦD [mm]
2.0
2.0
2.5
2.8
Plug in the
Pull out the
conductor.
screwdriver to fix
the conductor.
Φ
d
8
L
Φ
D

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents