[Setting example]
After power ON, changing from . display to change the (Run command source)
data.
Press [ESC] key to show
the function code
ESC
Press [ESC] key to move
on to the function group
ESC
Press [ESC] key Once to move
on to the function group .
Press Up key to change increase
function code
Press SET key to display the data of
Press up key to increase the
)
data
(
When data is changed, the display
starts blinking, which means that new
data has not been activated yet.
SET
:Fixes and stores the data and moves back to the function code
:Cancels the change and moves back to the function code
ESC
Function code xxx are for monitor and not possible to change.
Function codes xxx other than are reflected on the performance just after changing the data
(before pressing SET key), and there will be no blinking.
ESC
SET
)
(
SET
Display is solid lighting.
ESC
SET
Press SET key to set
and save the data
Data of
will be shown on the
display after the first power ON
.
20