Func.
Name
Code
Communication error
select
Communication error
time-out
Communication wait time
O input span calibration
OI input span calibration
Thermistor input (PTC)
span calibration
Debug mode enable
Communication selection
EzCOM start adr. of master
EzCOM end adr. of master
EzCOM starting trigger
Up/Down memory mode
selection
"C" Function
Description
Selects inverter response to
communications error.
Five options:
Trip
Decelerate to a stop and trip
Disable
Free run stop (coasting)
Decelerates to a stop
Sets the communications watchdog
timer period.
Range is 0.00 to 99.99 sec
0.0 = disabled
Time the inverter waits after
receiving a message before it
transmits.
Range is 0. to 1000. ms
Scale factor between the external
frequency command on terminals
L–O (voltage input) and the
frequency output,
range is 0.0 to 200%
Scale factor between the external
frequency command on terminals
L–OI (voltage input) and the
frequency output,
range is 0.0 to 200%
Scale factor of PTC input.
Range is 0.0 to 200%
Displays debug parameters.
Two option codes:
Disable
Enable <Do not set>
(for factory use)
Modbus-RTU
EzCOM
EzCOM<administrator>
01 to 08
01 to 08
Input terminal
Always
Controls speed setpoint for the
inverter after power cycle.
Two option codes:
Clear last frequency (return to
default frequency )
Keep last frequency adjusted
by UP/DWN
72
Run
Defaults
Mode
Initial data
Edit
02
0.00
0.
100.0
100.0
100.0
00
00
01
01
00
00
Units
sec.
msec.
%
%
%