Func.
Name
Code
Maximum-limit level of window
comparator (O)
Minimum-limit level of window
comparator (O)
Hysteresis width of window
comparator (O)
Maximum-limit level of window
comparator (OI)
Minimum-limit level of window
comparator (OI)
Hysteresis width of window
comparator (OI)
Operation level at O
disconnection
Operation level at OI
disconnection
Ambient temperature setting
Watt-hour clearance
Watt-hour display gain
Start frequency
Carrier frequency
Initialization mode (parameters
or trip history)
Country for initialization
Frequency scaling conversion
factor
STOP key enable
"b" Function
Description
Set range, {Min.-limit level () +
hysteresis width ()x2} to 100 %
(Minimum of 0%)
Set range, 0 to {Max.-limit level
() - hysteresis width
()x2} % (Maximum of 0%)
Set range, 0 to {Max.-limit level
() - Min.-limit level ()}/2 %
(Maximum of 10%)
Set range, {Min.-limit level ( +
hysteresis width ()x2} to 100 %
(Minimum of 0%)
Set range, 0 to {Max.-limit level
() - hysteresis width
()x2} % (Maximum of 0%)
Set range, 0 to {Max.-limit level
() - Min.-limit level ()}/2 %
(Maximum of 10%)
Set range, 0 to 100%, or "no"
(ignore)
Set range, 0 to 100%, or "no"
(ignore)
Set range is,
-10 to 50 C
Two option codes:
OFF
ON (press STR then clear)
Set range is,
1. to 1000.
Sets the starting frequency for the
inverter output, range is 0.10 to 9.99
Hz
Sets the PWM carrier (internal
switching frequency), range is 2.0 to
15.0 kHz
Select initialized data, five option
codes:
Initialization disabled
Clears Trip history
Initializes all Parameters
Clears Trip history and
initializes all parameters
Clears Trip history and
initializes all parameters and
EzSQ program
Mode 1
Specify a constant to scale the
displayed frequency for
monitor, range is 0.01 to 99.99
Select whether the STOP key on the
keypad is enabled, three option
codes:
Enabled
Disabled always
Disabled for stop
65
Run
Defaults
Mode
Initial data
Units
Edit
100.
%
0.
%
0.
%
100.
%
0.
%
0.
%
no
-
no
-
C
40
00
-
1.
0.50
Hz
10.0
kHz
00
01
1.00
00