Remote Control Fires - For Diagrams refer to section 2
4.5
Removing the RC Burner Assembly (RC models)
4.5.1
Prepare work area (lay down dust sheets etc.)
4.5.2
To remove the fascia, open the controls access door at the bottom of
the fascia. This will allow access to the fascia retaining screws, located
at the bottom left and right hand sides of the firebox. Remove these
screws and lift the fascia clear. Remove the coals, front ceramic from
the rail and fuel-bed base matrix. Remove all of the loose coals and
front ceramic rail. Unscrew the two pozi-drive fixing screws which
secure the burner heat shield and remove it from the fire.
4.5.3
Unscrew the 2 off burner retaining screws on the side brackets, the
burner should then be lifted out of the firebox.
NOTE : Please take care with the wiring loom
4.5.4
To refit the burner assembly, re-assemble in reverse order and carry out
a gas tightness test. Refit the coals referring to section 3
for the correct coal layout. The fascia can now be replaced by hooking
it over the top flange of the mounting frame and securing via the two
screws, accessed through the controls opening door.
4.6
Removing the Remote Gas Valve from the fire (RC models)
4.6.1
Prepare work area (lay down dust sheets etc.)
4.6.2
Remove the burner assembly as described in section 4.6.
4.6.3
Disconnect pilot, main and injector pipes and disconnect the wiring loom
thermocouple and ignition wire, the valve can then be removed.
Re-assemble in reverse order, Refit the coals referring to section 3
for the correct coal layout. The fascia can now be replaced by hooking
it over the top flange of the mounting frame and securing via the two
screws, accessed through the controls opening door.
4.7
Removing the Pilot Assembly (RC models)
Note : Because this appliance is fitted with an atmosphere sensing 'Oxy-
Pilot' it is not possible to replace the thermocouple separately, because the
thermocouple position is factory set to a tight tolerance. Any replacement of
parts on the pilot requires a complete new pilot assembly.
4.7.1
Prepare work area (lay down dust sheets etc.)
4.7.2
Remove the burner assembly as described in section 4.6
36