2.1

UNPACKING THE FIRE

Carefully lift the fire out of the carton. Remove the loose item packaging carefully
from the front of the appliance. Check the contents as listed :-
Packing Check List
1off
Fire box / burner assembly
1off
Boxed ceramic base, 2 piece ceramic front rail 11 synthetic coals or
pebbles
1off
Loose items bag.
1off
Installation and user instruction book (Combined)
1off
Flue restrictor baffle (for use in brick built chimneys and large diameter
e.g. 175mm flue applications).
2.2
INSTALLING THE FIRE BOX
Establish which type of flue you are intending to install the fire in to :-
225 x 225mm (9 inch x 9 inch) brick built chimneys
175mm (7 inch) diameter lined brick or stone flue, insulated pre-fabricated
metal flue box to BS 715 / BS EN 1856-2 or Pre-Cast Flue to BS EN 1858
When installing into 125mm (5 inch) diameter lined brick or stone flue, or
insulated pre-fabricated metal flue box to BS 715 / BS EN 1856-2 and
pre-cast flues the restrictor baffle must not be fitted.
A spillage test must always be carried out to check satisfactory
clearance of flue products, regardless of the type of flue the
appliance is being fitted to.
This product is designed to fit into a standard set of pre-cast starter
blocks, without needing to move the blocks within the wall cavity. If
the customer requires the product to be fitted at a height which
requires modification to the pre-cast flue system, please consult a
structural engineer regarding the re-positioning of the starter /
collection blocks of the pre-cast flue syste,
UNDER NO CIRCUMSTANCES SHOULD THE FIRE BE RECESSED INTO THE
GATHER BLOCK, OFFSET OR STRAIGHT FLUE BLOCKS.
SECTION 2

INSTALLATION OF FIRE

11