Removal Of The Burner Assembly (Remote Control Models); Removal Of The Valve (Remote Control Models); Removal Of The Oxy-Pilot Assembly (Remote Control Models) - Flavel Linear Installation, Maintenance & User Instructions

Decorative fuel-effect gas fires
Table of Contents

Advertisement

Remote Control Models – For Diagrams refer to Section 2
4.5
Removing the burner assembly from the fire.
4.5.1
Prepare work area (lay down dust sheets etc.)
4.5.2
Lift the fender and ash pan cover of the way and put them in a safe
location. Remove the loose coals from the fuel bed and front
ceramic rail. Remove the front ceramic from the rail. Unscrew the two
pozi-driv fixing screws which secure the burner heat shield and remove
it from the fire.
4.5.3
Isolate the gas supply and remove the inlet pipe from the appliance
inlet elbow. Unscrew and remove the four screws which retain the
burner.
4.5.4
To refit the burner assembly. Push the base of the control panel fully
into the fire and secure with the four screws. Refit the gas supply pipe
and carry out a gas tightness test. Refit the burner heat shield then refit
the coals / referring to section 3 for the correct coal / pebble layout.
The fender and ash pan cover or fascia can now be re-positioned.
4.6
Removing the Valve Assembly
4.6.1
Remove the burner assembly as in section 4.5
4.6.2
Remove the thermocouple retaining nut from the valve, remove the
main pipe, inlet pipe and pilot pipe from the valve.
4.6.3
Remove the valve retaining screws and remove. Re-assemble in
reverse order and carry out a gas tightness test. Re-fit coals
as shown in section 3. The fender and ash pan cover or fascia can now
be re-positioned.
4.7
Removing the Pilot Assembly.
Note : Because this appliance is fitted with an atmosphere sensing 'Oxy-
Pilot' it is not possible to replace the thermocouple separately, because the
thermocouple position is factory set to a tight tolerance. Any replacement of
parts on the pilot requires a complete new pilot assembly.
4.7.1
Remove the burner assembly as in section 4.5
4.7.2
Remove the thermocouple wires from the rear of the valve.
4.7.3
Loosen the pilot nut and remove two screw retaining the pilot assembly.