5.2.2
OPERATING THE FIRE - REMOTE CONTROL VARIANTS
a)
Open the controls access door. The control valve is positioned in the
centre of the fire when viewed from the front.
b)
To operate the appliance automatically via the remote control handset,
ensure that the on / off switch is switched to the "on" position as shown
below in Fig. 1
Fig. 1
"MANUAL"
Control Disk
On / Off Switch
c)
Switch the MANUAL control disc to the "ON" position. (Image above
shows "MANUAL" control disc set in the "MAN" position).
d)
Switch the main valve knob to the "OFF" position. (Image above shows
"MAIN VALVE" knob set in the "OFF" position.
e)
Press and hold the "STAR" button and "UP" button on the remote hand
set simultaneously, see Fig. 2 overpage for image of handset.
f)
The valve will then emit an audible beep and commence its ignition
sequence. When the pilot flame has been established, the control will
continue to beep whilst the thermocouple heats up. When the
thermocouple has reached operating temperature, it will allow gas to
flow to the burner and the burner will light at high rate heat input
(6.5kW).
"MAIN VALVE" Knob
42