Gas Tightness And Burner Pressure (Mc Models); Gas Tightness And Burner Pressure (Rc Models) - Flavel Vesta Installation, Maintenance & User Instructions

Inset fuel effect gas fire
Table of Contents

Advertisement

2.4
GAS TIGHTNESS AND BURNER PRESSURE (MANUAL CONTROL
MODELS)
a)
Remove the pressure test point screw from the inlet elbow and fit a
manometer.
b)
Turn on the main gas supply and carry out a gas tightness test.
c)
Depress the control knob and turn anti-clockwise to the position marked
pilot. Hold in the control knob for a few seconds to purge the pipe work
then press the igniter button. The burner should light, continue to hold
the control knob for a few seconds then turn to the full-on position.
d)
Check that the gas pressure is 20.0 mbar (+/- 1.0mbar) 8.0 in w.g.(+/-
0.4 in w.g.) for FVTC**MN & FVTP**MN models.
e)
Turn off the fire, remove the manometer and refit the pressure test point
screw. Check the pressure test point screw for gas tightness with the
appliance turned on using a suitable leak detection fluid or detector.
2.5
GAS TIGHTNESS AND BURNER PRESSURE (REMOTE CONTROL
MODELS).
a)
Remove the pressure test point screw from the inlet elbow and fit a
manometer.
b)
Turn on the main gas supply and carry out a gas tightness test.
c)
Depress both the round buttons on the handset. The fire will then
commence its ignition sequence and will light to high. See page 25
for full details of the operating method for the fire.
d)
Check that the gas pressure is 20.0 mbar (+/- 1.0mbar) 8.0 in w.g.(+/-
0.4 in w.g.) for FVTC**RN & FVTP**RN models.
e)
Turn off the fire, remove the manometer and refit the pressure test point
screw. Check the pressure test point screw for gas tightness with the
appliance turned on using a suitable leak detection fluid or detector.