Flavel Vesta Installation, Maintenance & User Instructions page 32

Inset fuel effect gas fire
Table of Contents

Advertisement

c)
Switch the MANUAL control disc to the "on" position. (Image above
shows "MANUAL" control disc set in the "MAN" position).
d)
Switch the main valve knob to the "OFF" position. (Image above shows
"MAIN VALVE" knob set in the "OFF" position.
e)
Press and hold the "STAR" button and "UP" button on the remote hand
set simultaneously, see Fig. 33 below for image of handset.
f)
The valve will then emit an audible beep and commence its ignition
sequence. When the pilot flame has been established, the control will
continue to beep whilst the thermocouple heats up. When the
thermocouple has reached operating temperature, it will allow gas to
flow to the burner and the burner will light at high rate heat input
(6.5kW).
Fig. 33
"LED" handset light
"STAR" / "OFF" button
g)
To reduce the heat input, press the "DOWN / STANDBY" button until the
flame reduces to the low rate heat input setting (3.5kW). If you continue
to hold the "DOWN / STANDBY" button, the burner flame will extinguish,
and only the pilot flame will remain lit. If you wish to turn off the
fire altogether, press the "STAR" / "OFF" button.
AFTER THE PILOT FLAME HAS BEEN EXTINGUISHED, IF YOU
WISH TO RE-LIGHT THE APPLIANCE YOU MUST WAIT AT LEAST
THREE MINUTES BEFORE TRYING TO RE-LIGHT THE FIRE.
32
"UP" button
"DOWN" / "STANDBY"
button