i)
Decide which side the gas supply is to enter the fire from. If concealed
pipe work is required plan the pipe run to enter the fire box through one
of the openings in the sides of the fire box below the fuelbed support
panel and connect to the isolating / inlet elbow. The gas connection to
the appliance should be made to the isolating / inlet elbow using 8mm
rigid tubing. There must be no soldered joints within the firebox. See
fig. 11 & 12 below for suggested concealed pipe layouts.
Fig. 11
Fig. 12
Builders
Opening
Note : Before breaking into the gas supply a pressure drop test should be
carried out to establish that the existing pipework is sound.
j)
Carefully withdraw the fire box from the opening to enable the gas
supply and fire fixing to be completed.
Approx.
40mm
Gas Supply
Approx.
40mm
Gas Supply
Purpose shaped gas
supply pipe is supplied
for R/H entry