(2) Detaching and refitting the drum separation claws

Follow the procedure below to replace the drum separation claws.
Cautions
Avoid direct sunlight or strong light when detaching and refitting the drum unit.
Never touch the drum surface when holding the drum unit.
Procedure
1. Remove the drum unit (see page 1-5-34).
2. Push the drum separation claws with the
minus driver from the top of the hole and
remove the claws.
3. Replace the drum separation claws and refit
all the removed parts.
Y110980-1
Drum
separation
claw
Drum
separation
claw
Service Manual
Drum
separation
claw
Drum
separation
claw
Figure 1-5-60
2KL/2KK
Hole
1-5-35