(2) Detaching and refitting the DP separation pad
Follow the procedure below to clean or replace the DP separation pad.
Procedure
1. Remove the DP feed pulley unit. (see page
1-5-2)
2. Push the inserted parts of the DP separation
pad and then remove the DP separation
pad.
3. Clean or replace the DP separation pad.
Refit all the removed parts.
Y108671-9
DP separation pad
Inserted part
Service Manual
DP separation pad
Inserted part
Figure 1-5-4
3K5