Detaching And Refitting The Drum Separation Claws - Olivetti d-Copia 1600 Service Manual

Hide thumbs Also See for d-Copia 1600:
Table of Contents

Advertisement

2HA/2HB

(2) Detaching and refitting the drum separation claws

Follow the procedure below to replace the drum separation claws.
Procedure
1. Remove the drum unit (see page 1-5-23).
2. Push the drum separation claws with the
minus driver from the top of the corner
hole and remove the claws.
3. Replace the drum separation claws and
refit all the removed parts.
1-5-24
Drum separation claws
Drum
separation
claw
Drum unit
Coner hole
Figure 1-5-53