2KL/2KK
Code
C6050
Abnormally low fuser thermistor tem-
perature
Fuser thermistor remains below 90 C/
194 F for 1 s.
C6400
Zero-cross signal error
Interrupt of the zero-cross signal does
not occur more than 1 s.
C7800
Broken external thermistor wire
The thermistor output value is 0.5 V or
less.
C7810
Short-circuited external thermistor
wire
The thermistor output value is 4.5 V or
more.
1-4-20
Contents
Causes
Check procedures/corrective measures
Poor contact in the
Reinsert the connector. Also check for conti-
fuser thermistor
nuity within the connector cable. If none,
connector termi-
remedy or replace the cable.
nals.
Broken fuser ther-
Measure the resistance. If it is
mistor wire.
the fixing thermistor.
Fuser thermistor
Check and reinstall if necessary.
installed incor-
rectly.
Fuser thermostat
Check for continuity. If none, replace the
triggered.
fuser thermostat.
Fuser heater
Check and reinstall if necessary.
installed incor-
rectly.
Broken fuser
Check for continuity. If none, replace the
heater wire.
fuser heater.
Poor contact in the
Reinsert the connector. Also check for conti-
connector termi-
nuity within the connector cable. If none,
nals.
remedy or replace the cable.
Defective power
Check if the zero-crossing signal is output
source PWB.
from YC2-2 on the power source PWB. If
not, replace the power source PWB.
Defective main/
Replace the main/engine PWB if C6400 is
engine PWB.
detected while YC2-2 on the power source
PWB outputs the zero-crossing signal.
Poor contact in the
Reinsert the connector. Also check for conti-
connector termi-
nuity within the connector cable. If none,
nals.
remedy or replace the cable.
Defective humidity
Replace the cassette PWB and check for
sensor.
correct operation.
Poor contact in the
Reinsert the connector. Also check for conti-
connector termi-
nuity within the connector cable. If none,
nals.
remedy or replace the cable.
Defective humidity
Replace the cassette PWB and check for
sensor.
correct operation.