Maintenance
item No.
Setting the default magnification ratio of the default cassette
U941
Description
Sets the default magnification ratio when paper selection of copy default setting is set to the default cassette.
Purpose
To be set according to user request.
Setting
1. Press the start key.
2. Select the magnification using the exposure adjustment keys.
Display
100
Aut
Initial setting: 100% magnification
3. Press the start key. The setting is set.
Completion
Press the stop/clear key. The screen for selecting a maintenance item No. is displayed.
Setting of amount of slack for feeding from DP
U942
Description
Adjusts the deflection generated when the DP is used.
Purpose
Use this mode if an original non-feed jam, oblique feed or wrinkling of original occurs when the DP is used.
Setting
1. Press the start key.
2. Select the item using the exposure adjustment keys.
Exposure
indicator
Exp. 1
Exp. 2
3. Press the interrupt key.
4. Place an original on the DP and press the start key to make a test copy.
5. Change the setting value using the zoom +/- keys.
The greater the value, the larger the amount of slack; the smaller the value, the smaller the amount of
slack.
If an original non-feed jam or oblique feed occurs, increase the setting value. If wrinkling of original
occurs, decrease the value.
6. Press the start key. The value is set.
Completion
Press the stop/clear key. The screen for selecting a maintenance item No. is displayed.
Y110980-1
Description
Description
100% magnification
Auto magnification selection
Description
Original feed motor (OFM)
(in simplex feed)
Original switchback motor (OSBM)
(in duplex feed)
Service Manual
Setting range
Initial setting
-10 to 20
0
-10 to 20
0
2KL/2KK
1-3-61

Advertisement