Olivetti d-copia 1800 Service Manual page 58

Hide thumbs Also See for d-copia 1800:
Table of Contents

Advertisement

2KL/2KK
Maintenance
item No.
Adjusting the scanner leading edge registration
U066
Description
Adjusts the scanner leading edge registration of the original scanning.
Purpose
Make the adjustment if there is a regular error between the leading edges of the copy image and original.
Adjustment
1. Press the start key.
Description
Scanner leading edge registration
2. Press the interrupt key.
3. Place an original and press the start key to make a test copy.
4. Change the setting value using the zoom +/- keys.
For copy example 1, decrease the value. For copy example 2, increase the value.
5. Press the start key. The value is set.
Caution
Check the copy image after the adjustment. If the image is still incorrect, perform the following adjustments in
maintenance mode.
U066
Completion
Press the stop/clear key. The screen for selecting a maintenance item No. is displayed.
1-3-20
Scanner leading edge registration
Original
U403
U071
(P.1-3-51)
(P.1-3-24)
Service Manual
Description
Setting
Initial
range
setting
-32 to 20
0
Copy
Copy
example 2
example 1
Figure 1-3-9
U404
(P.1-3-52)
Change in
value per step
0.17 mm