2KL/2KK
Maintenance
item No.
Adjusting margins for scanning an original from the DP
U404
Description
Adjusts margins for scanning the original from the DP.
Purpose
Make the adjustment if margins are incorrect when the optional DP is used.
Caution
Before making this adjustment, ensure that the following adjustments have been made in maintenance mode
U402
(P.1-3-50)
Adjustment
1. Press the start key.
2. Select the item using the exposure adjustment keys.
Exposure
indicator
Exp. 1
Exp. 2
Exp. 3
Exp. 4
3. Press the interrupt key.
4. Place an original on the DP and press the start key to make a test copy.
5. Change the setting value using the zoom +/- keys.
Increasing the value makes the margin wider, and decreasing it makes the margin narrower.
6. Press the start key. The value is set.
Completion
Press the stop/clear key. The screen for selecting a maintenance item No. is displayed.
1-3-52
U403
U404
(P.1-3-51)
Description
Left margin
Leading edge margin
Right margin
Trailing edge margin
Leading edge margin
(3.0±2.5 mm)
Left margin
(2.5+1.5/-2.0 mm)
Trailing edge margin
(3.0±2.5 mm)
Service Manual
Description
Setting
range
0.0 to 10.0
0.0 to 10.0
0.0 to 10.0
0.0 to 10.0
Right margin
(2.5+1.5/-2.0 mm)
Figure 1-3-19
Initial
Change in
setting
value per step
2.0
0.5 mm
3.0
0.5 mm
2.0
0.5 mm
2.0
0.5 mm