Ip Plus Function; Noise Blanker; D Adjusting The Nb Level And Time - Icom IC-7300 Basic Manual

Hide thumbs Also See for IC-7300:
Table of Contents

Advertisement

SelectingtheIFfiltershape(Continued)
• SHARP
This selection is to emphasize the passband width of
thefilter.Thefilterhasanalmostidealshapefactor.
Signalsoftheoutofpassbandareextremelyfiltered
out and it gives you better audio quality.
• SOFT
  T hefiltershouldersareroundlyformedasinanalog
filters.Thisdecreasesnoisecomponentsinthe
highandlowfrequenciesofthefilterpassband
and increases the S/N of the target signal. These
characteristics play an effective role in picking up
very weak signals in the 50 MHz band, for example.
The shape factor is kept, and the sharpness of the
bandpass is excellent.
IPPlusfunction
The IP Plus function improves the Intermodulation
Distortion (IMD) quality by exerting the direct sampling
system performance.
This function optimizes the Analog/Digital Converter
(ADC) against the distortion when you receive a
strong input signal. It also improves the Third-order
Intercept Point (IP3) while minimizing the reduction of
the receive sensitivity.
1. Push
.
FUNCTION
• The FUNCTION screen is displayed.
2. Touch [IP+].
LTouch [IP+] to turn the IP Plus function ON or OFF.
L Select ON to prioritize the IP quality, and select OFF
to prioritize the receive sensitivity.
3. To close the FUNCTION screen, push
• "IP+" is displayed when ON is selected.
NoiseBlanker
The Noise blanker eliminates pulse-type noise such
as the noise from car ignitions.
The Noise blanker cannot be used in the FM mode.
Push
NOTE:WhenusingtheNoiseBlanker,receivedsignals
may be distorted if they are excessively strong or the noise
is other than a pulse type. In that case, turn the OFF Noise
Blanker,orshallowtheDEPTHontheNBmenu.
See the description below for details.
D AdjustingtheNBlevelandtime
To deal with various type of noise, you can adjust the
attenuationlevelandnoisewidthintheNBmenu.
1. Hold down
•  T urnsONtheNoiseBlankerandopenstheNBmenu.
2. Touch the adjusting item.
(Example: DEPTH)
3. Adjust the level.
(Example: 8)
LEVEL
AdjustthelevelwheretheNoiseBlankeractivates
.
EXIT
between 0 and 100%.
Displayed
DEPTH
Adjust the noise attenuation level between 1 and 10.
WIDTH
Adjust the blanking duration time between 1 and 100.
4-5
RECEIVING AND TRANSMITTING
toturntheNoiseBlankerONorOFF.
NB
NB
for 1 second.
4
1
2
3
4
Displayed
5
6
7
8
9
10
11
12
13
14
15
16
Rotate
17
Push
18
19
20
(Default: 50%)
21
(Default: 8)
(Default: 50)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents