The following features are changed in, or added to, the IC-7300.
■ Scope operation �������������� 1
■ MENU screen ��������������� 2
■ PRESET menu ��������������� 2
■ Multi-function dial �������������� 3
■ Touch screen display ������������ 4
■ Band stacking register ����������� 4
■ Front Key Customize function �������� 5
■ MIC Key Customize function ��������� 6

■ Scope operation

• The Scroll mode is added.
• When the scope span or Edge frequency is
changed, such as by touching [SPAN] or [EDGE],
the selected scope span or the selected Edge
frequency display is enlarged.
• In the SCOPE SET menu, "Marker Position (FIX
Type)" is renamed to "Marker Position (FIX Type/
SCROLL Type)."
• The maximum number of Fixed Edges for each
band is increased from 3 to 4.
• Each band memorizes the Reference level.
• When the Scope screen is open, holding down
[M.SCOPE] for 1 second closes the screen.
INFORMATION
IC-7300 Version 1.40
■ REF Adjust ���������������� 7
■ CI-V USB Port ��������������� 7
■ Firmware Update screen ���������� 7
■ Keyboard entry ��������������� 7
■ CI-V commands �������������� 8
DScroll mode
Displays signals within a selected span. When the
operating frequency moves outside of the screen, the
displayed frequency range is automatically scrolled.
1. Display the SPECTRUM SCOPE screen.
MENU
2. Touch [CENT/FIX] for 1 second to select the
Scroll mode.
• When changing the Center mode to the Scroll mode,
"SCROLL-C" is displayed.
You can change the scope span by touching [SPAN].
• When changing the Fixed mode to the Scroll mode,
"SCROLL-F" is displayed.
You can change the Edge frequencies by touching
[EDGE].
3. Touch [CENT/FIX] to return to the previous mode.
• When returning to the Center mode, the scope span
does not return to the previous setting.
• When returning to the Fixed mode, the Edge
frequencies return to the last selected "Fixed Edges."
If the operating frequency is above the upper Edge
frequency, or below the lower Edge frequency, "<<"
or ">>" is displayed in the upper side corners of the
SPECTRUM SCOPE screen.
1
» SCOPE
Edge (Upper frequency)
Grid (frequency/level)
When in the SCROLL-C mode,
Edge (Lower frequency)
When in the SCROLL-C mode,
is displayed.
Operating frequency (moves)
is displayed.

Advertisement

Table of Contents
loading

Summary of Contents for Icom IC-7300

  • Page 1: Table Of Contents

    INFORMATION IC-7300 Version 1.40 The following features are changed in, or added to, the IC-7300. ■ Scope operation �������������� 1 ■ Tone Control settings in the Data mode ���� 7 ■ MENU screen ��������������� 2 ■ REF Adjust ���������������� 7 ■...
  • Page 2: Menu Screen

    TIP: Depending on your software, you may need to change the “CI-V Address” setting. For example, you use a software that is not compatible with the IC-7300. In that case, you may be able to use the software by setting “CI-V Address” to another transceiver’s address.
  • Page 3: Multi-Function Dial

    ■ Multi-function dial The function of the Multi-function dial ( ) is enhanced. MULTI * On the Multi-function menus, touch the item for 1 When the Multi-function menu is closed, MULTI second to assign the function to MULTI be enabled to adjust functions by pushing or touching To cancel the function assigned to , touch the MULTI...
  • Page 4: Touch Screen Display

    ■ Touch screen display The appearance or location of the following indicators on the screen are changed, according to the Multi-function dial ( ) function enhancement. MULTI 1 2 3 ■ Band stacking register 1 M1~M8/T1~T8 icons The location of “IP+” and “OVF” icons is moved to 6.
  • Page 5: Front Key Customize Function

    ■ Front Key Customize function AUTO You can change the , and keys function. ▲ ▼ VOX/BK-IN TUNE » SET > Function > Front Key Customize MENU ●: Default setting, ○: Assignable, N/A: Not assignable Function Description [VOX/BK-IN] [AUTOTUNE] [▲] [▼] •...
  • Page 6: Mic Key Customize Function

    ■ MIC Key Customize function You can change the microphone’s [UP]/[DOWN] keys function. » SET > Function > MIC Key Customize MENU [UP] (Default: UP (VFO: kHz)) [DN] (Default: DOWN (VFO: kHz)) Function Description Function Description No function In the SSB, AM, or FM mode Voice/ •...
  • Page 7: Tone Control Settings In The Data Mode

    ■ Tone Control settings in the ■ Keyboard entry Data mode On the Full Keyboard screen, the Capital Lock function is not canceled, even if you toggle between In the Data mode, the Tone Control settings are the alphabet and numeric modes. automatically disabled.
  • Page 8: Ci-V Commands

    ■ CI-V commands The following commands are changed in, or added to DCommand formats the conventional Command table. • [VOX/BK-IN] setting Command: 1A 050198 Cmd. Sub cmd. Data Description 0198 See the right. Send/read the Front key customize Data Function [VOX/BK-IN] setting VOX/BK-IN 0199 See the right.
  • Page 9 ■ CI-V commands D Command formats • MIC Key Customize setting • Bandscope edge frequency settings Command: 1A 050202, 050203 Command: 1A 050112 ~ 1A 050150 1A 050204 ~ 1A 050216 Data Function No function X 0 X X X X DOWN UP (VFO: kHz) DOWN (VFO: kHz)
  • Page 10 • In the Center mode: Center frequency and span are sent. Span (kHz) See page 19-9 of the IC-7300 FULL MANUAL 0 0 0 0 X X X X 0 0 0 0 2500 for Operating frequency data, and the Scope span settings (2 ~ 6) to the right.
  • Page 11 ■ CI-V commands D Command formats • Scope Fixed edge frequency settings Command: 27 1E X X X X X X X 0 0 X X X X X X X X 0 0 Lower edge Higher edge LEntry of less than 100 Hz digits are ignored. 1 Selectable Frequency ranges: Data Frequency range (Hz)
  • Page 12 • An inhibit timer for the USB connection is added. z CI-V commands are added. (p. 2) Before updating, see Section 15 ‘UPDATING THE FIRMWARE’ in the IC-7300 Full manual, that is included on the CD supplied with your transceiver.
  • Page 13 ■ Additional CI-V commands (Full manual on the CD) The following commands are added to the conventional Command table. Cmd. Sub Cmd. Data Description 0196 below Send/read SSB-D TX bandwidth 0197 00/01 Inhibit Timer at USB connection (00=OFF, 01=ON) * Send/read data •...

Table of Contents