13. Open the developer pack [J]
14. While turning the black gear [K], slowly move the pack left and right and pour half of the
developer over the auger [L].
15. Continue to rotate the black gear until the developer is level.
While continuing to turn the black gear, slowly move the pack left and right and pour the remaining half
of the developer over the augur until the developer is level.
• Be careful. Do not spill developer on the gears or sponges.
• If you accidentally spill developer on the gears or sponges, remove it with a magnet or the tip of a
magnetized screwdriver.
PCU Reassembly
Reassemble the PCU in this order:
Photoconductor Unit (PCU)
217