4. Appendix: Service Program Mode Tables
Function Flag
Enables or disables the remote service function.
3*
[0 to 1 / 0 / 1 /step]
0: Disabled, 1: Enabled
NOTE: This SP setting is changed to "1" after @Remote register has been completed.
SSL Disable
Uses or does not use the RCG certification by SSL when calling the RCG.
7*
[0 to 1 / 0 / 1 /step]
4
0: Uses the RCG certification
1: Does no use the RCG certification
RCG Connect Timeout
8*
Specifies the connect timeout interval when calling the RCG.
[1 to 90 / 30 / 1 second /step]
RCG Write Timeout
9*
Specifies the write timeout interval when calling the RCG.
[0 to 100 / 60 / 1 second /step]
RCG Read Timeout
10*
Specifies the read timeout interval when calling the RCG.
[0 to 100 / 60 / 1 second /step]
Port 80 Enable
Enables/disables access via port 80 to the SOAP method.
11*
[0 or 1 / 0 / – ]
0: Disabled, 1: Enabled
RFU (Remote Firmware Update) Timing
Selects the RFU timing.
13*
[0 or 1 / 1 / – ]
0: RFU is executed whenever update request is received.
1: RFU is executed only when the machine is in the sleep mode.
206