CONSOLE DIAGNOSTIC TESTS

The following tests must be performed while the console is in the DIAGNOSTIC
mode. To activate the DIAGNOSTIC mode, press the [+ ARROW], [1], [0], [7],
[ENTER]. If the console fails any test, the console should be replaced or ex-
changed.
Display Test
Use this test if the console display or the text bar exhibits blank spots during use.
This test checks for inoperable light emitting diodes (LEDs) in the console display
and the text bar. If any LED will not light, replace the console.
1.
Press [0] to start the test.
2.
All LEDs in the console display and text bar should flash.
3.
Press [CLEAR] to end the test.
Speaker Test
Use this test to make sure the console speaker is fully operational. The speaker
will ascend and then descend through the musical scale.
1.
Press [1] to start the test.
2.
Press [ENTER] to pause the test. Press [CLEAR] to end the test.
Keypad Test
Perform this test if you are having trouble entering data into the console. If you
cannot enter the DIAGNOSTIC mode code due to an inoperable keypad, replace
the console.
1.
Press [2] to start the test.
2.
The display LEDs will light up in an L-shaped formation, representing
the keypad matrix. Pressing a button on either the exercise program
keypad or the function keypad will light an LED within the outline on
the display that corresponds to that button's position on the console.