Operating Instructions
Instructions for the data fields
a.
Digital input terminal of I/O Connector activates the alarm trigger.
Please refer to Section 3.1 Interfacing to the I/O Connector.
b.
Active Time of Trigger
The active trigger time can be set in the primary time and the
secondary time. The secondary time is the supplement of the primary
time.
Always: always activates the alarm trigger.
Operational between: Sets the starting and stopping time of the
primary time. The day of the week can be set by checking.
Starting and stopping time is set only in 24 h time mode.
Alarm enable condition: Please select the [Rising] (GND to Open
High) or [Falling] (Open High to GND) of digital input terminal of the I/
O Connector.
c.
Secondary time is active trigger time except the primary time.
Alarm enable condition: Please select the [Rising] (GND to Open
High) or [Falling] (Open High to GND) of digital input terminal of the I/
O Connector.
d.
Sets the image resolution and image quality.
Image resolution: 640 x 480/320 x 240/160 x 120
Image quality: Favor Clarity/Standard/Favor Motion
e.
The Pre and/or Post trigger can be set on the Buffering Image. Please
check the box.
f.
Image Frequency: Sets the image frequency to send.
Maximum number of images per each trigger:
Selects the number of buffering frames from numbers 1 to 400.
g.
Selects Transfer Method.
Non transfer: Activates the only buffering .
FTP: Enters the server address*
Login ID*
name*
Over write setting:
Selects [Over Write...] to over write the transferred image or [Add
time...] to save each transferred image.
and password*
2
including full path.
2
or Host Name*
1
to access the FTP server and upload file
2
, Port no. (1 – 65535),
2
69