- Fuser Error
 
OPEN Heat
Warm-Up
Less than 60℃
at more than 20
seconds
Stand-Byor
N/A
Recoverable
Error State for
Over Heat only
Printing
N/A
Power Save
N/A
Low Power
N/A
Other
N/A
Service Manual
Product Specifications and Features
LOW Heat
- Less than Warm Up Ref.
Temp-10℃ & for more than 20
seconds in Warm Up end time
(Not checking in case that motor
start temp(100℃) is not arrived)-
In case that the tempature is
not rising for 6 sec (Check at
WarmUp Ref Temp-30℃)
Less than Stand-By Ref. Temp-
40℃ & For more than 10
seconds
Less than Printing Ref. Temp-
20℃ & For more than 10
seconds.
N/A
N/A
N/A
2-41
OVER Heat
Higher than 230℃(240℃) &For
continuous 30 seconds (5 sec)
- Higher than 230℃(240℃) & For
continuous 30 seconds(5 sec)
- StandBy Ref Temp+10℃& for
more than 3 min.
- Higher than 220℃(230℃) & For
continuous 20 seconds(3 sec)
- Higher than 220℃(230℃) & For
continuous 20 seconds(3 sec)
- StandBy Ref Temp+10℃& for
more than 3 min.
- Higher than 220℃(230℃) & For
continuous 20 seconds(3 sec)
- StandBy Ref Temp+10℃& for
more than 3 min.
Higher than 220℃(230℃) & For
continuous 20 seconds(3 sec)