Muratec MFX-C4000 Field Engineering Manual page 162

Hide thumbs Also See for MFX-C4000:
Table of Contents

Advertisement

Code
Displayed Name
102-0030
T2 Feed Sensor (or Door
Open)
102-0031
T3 Feed Sensor (or Door
Open)
102-0033
Regi. Sensor
102-0034
Exit Sensor
102-0035
Duplex Jam1 Sensor
102-0036
Duplex Jam2 Sensor
105-0000
Yellow MHV Bias
105-0001
Magenta MHV Bias
105-0002
Cyan MHV Bias
105-0003
Black MHV Bias
105-0004
Yellow MHV Bias Read
105-0005
Magenta MHV Bias Read
105-0006
Cyan MHV Bias Read
105-0007
Black MHV Bias Read
106-0000
Yellow Dev Bias
106-0001
Magenta Dev Bias
106-0002
Cyan Dev Bias
106-0003
Black Dev Bias
107-0000
Yellow THV Bias Read
107-0001
Magenta THV Bias Read
107-0002
Cyan THV Bias Read
107-0003
Black THV Bias Read
107-0004
iTHV(+) Bias
107-0005
iTHV Bias Read
107-0006
iTHV(-) Bias
Fuser Temperature A
109-0000
109-0001
Fuser Temperature B
Service Manual
Alignment & Troubleshooting
Detect when a paper is at T2 Feed sensor. (optional)
Detect when a paper is at T3 Feed sensor. (optional)
Detect when a paper is at Regi. sensor.
Detect when a paper is at Exit. sensor.
Detect when a paper is at Duplex Jam1 sensor.
Detect when a paper is at Duplex Jam2 sensor.
Yellow MHV bias voltage on at normal drive level
Magenta MHV bias voltage on at normal drive level
Cyan MHV bias voltage on at normal drive level
Black MHV bias voltage on at normal drive level
Yellow Detect what the MHV value is on the MHV
Roller
Magenta Detect what the MHV value is on the MHV
Roller
Cyan Detect what the MHV value is on the MHV
Roller
Black Detect what the MHV value is on the MHV
Roller
Yellow Dev bias voltage on at normal drive level
Magenta Dev bias voltage on at normal drive level
Cyan Dev bias voltage on at normal drive level
Black Dev bias voltage on at normal drive level
Detect what the THV value is on the THV Roller
Detect what the THV value is on the THV Roller
Detect what the THV value is on the THV Roller
Detect what the THV value is on the THV Roller
iTHV plus bias voltage on at normal drive level
Detect what the THV value is on the iTHV Roller
iTHV minus bias voltage on at normal drive level
Detects what the temperature A is on fuser.
Detects what the temperature B is on fuser.
4-56
Meaning
State
Displayed
High[low]
High[low]
High[low]
High[low]
High[low]
High[low]
On[Off]
On[Off]
On[Off]
On[Off]
On[Off]
On[Off]
On[Off]
On[Off]
On[Off]
On[Off]
On[Off]
On[Off]
Numeric 3
digits
Numeric 3
digits
Numeric 3
digits
Numeric 3
digits
On[Off]
On[Off]
Numeric 3
digits
Numeric 3
digits