Muratec MFX-C4000 Field Engineering Manual page 44

Hide thumbs Also See for MFX-C4000:
Table of Contents

Advertisement

HVPS_S (High Voltage Power Supply_Small) supplies High Voltage power to Drum-cartridge (Developer),
Fuser, Saw-plate (T2-Unit).
HVPS_L/S_ connection (from HVPS_L)
• Specification
Channel
AC/DC
DC-
MHV
AC
DEVE
DC-
T1
DC+
DC+
T2
DC-
Saw Plate
DC-
Fuser Bias
DC+
• Constant current outputs in T1/T2 channels.
• Individual T1 channels for each color.
• Alternative DC +/- outputs between image & non-image periods in T2.
• AC + DC MHV Bias.
• Rated loads in all channels could be change according to the environmental conditions.
• All output channels can be adjusted by using volume control components.
Service Manual
Product Specifications and Features
Fuser-bias (to Fuser)
No.
Type
Constant-V
PWM Duty
4
-
PWM Duty
4
Constant-V
PWM Duty
4
Constant-I
PWM Duty
Constant-I
PWM Duty
1
Constant-V
1
Constant-V
PWM Duty
1
Constant-V
PWM Duty
Saw-plate (to T2 Unit)
DEVE_Y/M/C/K (to Drum-cartridge)
Rated
Control
Load
250 pF
400 MΩ
90 MΩ
100 MΩ
80 MΩ
Volume
NO
NO
2-30
Output
Output
Range
-700 V
0 ~ -1800 V
1.6 KVpp 1.0 ~ 3.2 Vpp
-500 V
0 ~ -800 V
14 uA
0 ~ 40 uA
30 uA
0 ~ 50 uA
-1300 V
-
-1000 V
0 ~ -2.4 KV
1000 V
0 ~ 1.5 KV
Load
Range
0.1~3 mA
0 ~ 30 uA
0 ~ 3.5 KV
0 ~ 6.5 KV
0 ~ 20 uA
0 ~ 40 uA
0 ~ 20 uA

Advertisement

Table of Contents
loading

Table of Contents