Equipment - System - Lennox iComfort S30 Installation And Setup Manual

Color touchscreen programmable wi-fi communicating thermostat
Hide thumbs Also See for iComfort S30:
Table of Contents

Advertisement

EQUIPMENT
Selections listed in this section are dependent on system hardware configuration.
Not all options will be available.
NOTE: When changing the default settings for any parameter, there is a possibility
that it will affect the settings for another parameter. If this happens, a pop-up
message will be displayed listing the other affected parameters and their new
automatically set values.
display
equipment name
alerts
Changing Temperature Control Mode
filter 1 timer selection
has affected the following parameters:
filter 2 timer selection
name
uv bulb timer selection
Temperature Control
continues blower cmf
zone 1
Wall Insulation
zone 2
zone 3
SMART HUB
The following is a complete list of all possible parameters under System.
Parameters actually available are dependent on the Lennox communicating
equipment type detected and non-communicating equipment added.
ABOUT
This screen provides information concerning language supported, equipment type
name, control software revision, model, control mode number, control serial
number, control hardware revision, protocol revision number, device product level,
24VAC average power consumption, 24VAC peak power consumption, compatible
devices list, application code memory size and micro-controller part number.
EQUIPMENT NAME
A unique name can be assigned to this component. Name can be up to 29
characters. Name can consist of letters, numbers, special characters and spaces.
warning
new value
1
Mode
2
ok
PUREAIR TIMER SELECTION
The PureAir™ Air Purification System combines multiple air purification
technologies into a single, state-of-the-art, air purifier.
be based on either calendar time or system run-time. Default is calendar time.
SMOOTH SETBACK RECOVERY
When enabled, smooth set back begins recovery up to two hours before the
programmed time so that the programmed temperature is reached at the
corresponding programmed event time. Assume 12°F per hour for first-stage
gas/electric heating and 6°F per hour for first-stage compressor based heating or
cooling. With Smooth Set Back disabled, the system will start a recovery at the
programmed time. Options are enabled or disabled. Default is enabled.
GAS HEATING ACTIVATION TEMP DIFFERENCE
Range is 0.5 to 10°F. Default is 1.5°F and can be set in increments of 0.5°F.
Adjustments are in increments of 0.5°F. When the system is dual-fuel and steady
state while operating at full HP demand, this is the amount of °F below the set point
that is allowed before allowing to switch to gas heat.
ELECTRIC HEAT CONTROL MODE (XC17, XP17, XC21 AND XP21 ONLY)
In heat pump applications, the electric heat is staged to provide supplemental heat
to meet desired comfort levels. When the electric heat section is used in
applications that do not have a heat pump, the elements are staged to limit heat so
that it meets heating demands only. Options are standard and EvenHeat. Default is
EvenHeat.
EVENHEAT DISCHARGE TEMP
When in EvenHeat Control Mode, the iComfort
sections to maintain a constant Discharge Air Temperature. The system must have
a discharge sensor connected to the system to show this parameter.
NOTE: Not selectable on XC/XP25 applications. Electric heat elements will be
staged on by the demand of the iComfort
Range is 85 to 130ºF. Default is 85ºF. Adjustments can be made in increments of
15ºF.
GAS HEAT CONTROL MODE (SLP98 ONLY)
Options are Staged, Load Tracking Variable Capacity and Variable Capacity.
Default is Staged.
Some furnaces can be configured to provide up to four stages of gas heat
operation. When staged heating is chosen, the iComfort
between 1, 2, 3 and 4 stages of heat. Single*stage heat: 1st stage provides 100%
of full capacity.
S
Two*stage heat: 1st stage provides 70% of full capacity; 2nd stage provides
100% of full capacity.
17
This selection allows timer to
®
S30 will stage the electric heat
®
S30.
Staged
®
S30 allows you to choose

Hide quick links: