NOTE: When a Lennox Equipment Interface Module (EIM) is used and configured
either as a furnace or air handler, then the component would appear as either
EIM-Furnace or EIM-Air Handler. When using a EIM the outdoor unit may be either
a Lennox communicating or any standard 24VAC non-communicating unit.
NOTE: Not all equipment may be visible from the equipment found system screen.
Use a finger to swipe up to access additional information (if applicable) listed at the
bottom of the system box.
If non-communicating equipment needs to be added, it can be done so from this
screen.
NON-COMMUNICATING EQUIPMENT
When selecting the non-communicating (24VAC) equipment icon a screen will
appear listing various equipment that can be added. When selecting a applicable
component, a green check will appear next to the item.
NOTE - Also a temporary dialog box will appear indicating: Updating - Wait while we
check for dependencies.
NOTE: Selecting an outdoor unit type only appears if a communicating outdoor unit
is not detected by the system. Selections are one or two stage heat pumps or air
conditioners. Other equipment that can be added are humidifiers and
dehumidifiers.
Once completed press done which will display the equipment now screen. There
the additional non-communicating equipment will now be displayed along with the
communicating equipment.
Once completed press continue.
REMINDERS
This screen allows you to set reminders as either disabled or 3, 6, 12 or 24 months
and also custom by specific date.
Reminders may be set for replace filter 1, replace filter 2, replace UV blub, replace
humidifier pad, PureAir maintenance and maintenance reminder. Once a reminder
is set for a specific item, press done to return to the previous screen.
Once completed press continue.
IHARMONY ZONING
This screen will only appear if the iHarmony® zoning system is detected.
This screen allows you to rename each zone using provided preset names or
custom name. This screen will not appear if iHarmony component hardware is not
detected by the system.
Press on any zone to rename it. A screen will display that list several predefined
names that can be used which are master bedroom, guest bedroom, kitchen, living
room, media room, dining room library or custom. When a predefine name is
selected, a green check-mark will appear next to the selected name.
When creating a custom name, select custom, enter a name and press back to
return to the previous screen. A new unique zone name can be created for all four
zones.
Once done, press done to return to the zoning screen and verify the new name is
being used for the specific zone.
Once completed press continue.
SET UP AIRFLOW PER ZONE
This screen will allow the installer to setup the airflow per zone. The types of
circulation per zone are:
S
Blower Circulation Airflow (gray) which includes total, assigned, minimum
and maximum airflow
S
Heating Circulation Airflow (red) which includes total, assigned, minimum
and maximum airflow
S
Cooling Circulation Airflow (blue) which includes total, assigned, minimum
and maximum airflow.
Press on the circled green arrow to select a specific zone. The zone will explain to
allow the installer to adjust CFMs for each circulation airflow type. Use the plus and
minus buttons to adjust CFMs up and down.
Once completed press continue. The next screen that will appear is the Dealer
Control Center.